Please use this identifier to cite or link to this item:
https://hdl.handle.net/20.500.13087/2645
Title: | Ultrasound-assisted cloud point microextraction of certain preservatives in real samples and determination by HPLC | Authors: | Güray, Tufan Akil, Filiz Hümeyra Uysal, Ülkü Dilek |
Keywords: | Food Samples Brilliant Blue Water Samples Parabens Extraction Liquid Chromatography Cosmetics Mixtures Products |
Issue Date: | 2022 | Publisher: | Royal Soc Chemistry | Abstract: | Ultrasound-assisted cloud point microextraction (UA-CPME) was performed for certain preservatives (p-hydroxy benzoic acid and its alkyl esters, methyl, ethyl, propyl and butyl parabens). Then, an HPLC method was developed for their simultaneous determination in pharmaceutical and cosmetic samples. The chromatograms of these substances were recorded on a C18 column using a gradient elution technique with various solvent systems at different flow rates and at 254 nm wavelength using a diode-array detector (DAD). The analysis conditions found by the classical method were optimized using the Box-Behnken design (BBD). In the design, the effect of each factor was examined with 3 and 4 factors for UA-CPME and HPLC analyses, respectively. The brij 58 concentration (BC), Na2SO4 amount (SA) and extraction time (ET) for UA-CPME, and the mobile phase 1 (MP1) ratio, mobile phase 2 (MP2) ratio, flow rate (FR) and column temperature parameters for HPLC analysis were obtained for the investigated levels. The factors affecting the resolution were determined by applying regression analysis to the experimental results. The analysis of variance (ANOVA) test was applied to ensure result reliability. The ANOVA test was used to determine the reliability of the results. A model was created with the obtained data. The developed method was validated by examining linearity, reproducibility, accuracy, limit of quantification and limit of the detection. Methyl paraben (with 0.148% RSD value and 0.060% relative error), and propyl paraben (with 0.149% RSD value and 0.120% relative error) were determined in the syrup sample by the developed method. Methyl paraben with recovery values of (98.32-99.42)% and ethyl paraben with recovery values of (99.17-99.41)%, were determined in a hand cream. | URI: | https://doi.org/10.1039/d1ay01887f https://hdl.handle.net/20.500.13087/2645 |
ISSN: | 1759-9660 1759-9679 |
Appears in Collections: | PubMed İndeksli Yayınlar Koleksiyonu Scopus İndeksli Yayınlar Koleksiyonu WoS İndeksli Yayınlar Koleksiyonu |
Show full item record
CORE Recommender
Items in GCRIS Repository are protected by copyright, with all rights reserved, unless otherwise indicated.